• 128.97 KB
  • 53页

附件5:气体绝缘金属封闭开关设备技术标准(附编制说明)

  • 53页
  • 当前文档由用户上传发布,收益归属用户
  1. 1、本文档共5页,可阅读全部内容。
  2. 2、本文档内容版权归属内容提供方,所产生的收益全部归内容提供方所有。如果您对本文有版权争议,可选择认领,认领后既往收益都归您。
  3. 3、本文档由用户上传,本站不保证质量和数量令人满意,可能有诸多瑕疵,付费之前,请仔细先通过免费阅读内容等途径辨别内容交易风险。如存在严重挂羊头卖狗肉之情形,可联系本站下载客服投诉处理。
  4. 文档侵权举报电话:19940600175。
'GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.目次1总则····················································································································································12.使用条件···········································································································································22.1正常使用条件·························································································································22.2特殊使用条件·························································································································33术语和定义········································································································································54技术要求············································································································································54.1额定电压·································································································································54.2额定绝缘水平·························································································································54.3额定频率·································································································································74.4额定电流与温升·····················································································································74.5额定短时耐受电流·················································································································74.6额定峰值耐受电流·················································································································84.7额定短路持续时间·················································································································84.8断路器及隔离开关·················································································································84.9其他设备·······························································································································104.10母线·····································································································································104.11绝缘子·································································································································104.12操动机构·····························································································································104.13用作绝缘的气体的额定密度和最小运行密度·································································105设计和结构······································································································································105.1一般要求·······························································································································105.2对GIS中六氟化疏气体的要求··························································································115.3支撑、底架及接地···············································································································115.4控制和辅助设备···················································································································125.5动力合闸·······························································································································145.6贮能合闸·······························································································································155.7脱扣器操作···························································································································155.8气体监测系统及气体压力闭锁装置···················································································175.9铭牌·······································································································································175.10防护等级·····························································································································185.11内部故障·····························································································································195.12外壳·····································································································································205.13隔室·····································································································································215.14防爆·····································································································································215.15联锁·····································································································································225.16断路器的其他要求·············································································································235.17隔离开关和接地开关·········································································································235.18电流互感器·························································································································235.19电压互感器·························································································································235.20避雷器·································································································································235.21对电缆绝缘试验的规定·····································································································235.22GIS出线的连接···················································································································235.23伸缩节·································································································································255.24母线·····································································································································255.25油漆·····································································································································25I GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.5.26压缩机及管道系统·············································································································255.27二次回路及就地控制柜·····································································································266型式试验··········································································································································266.1概述·······································································································································266.2绝缘试验·······························································································································276.3无线电干扰试验···················································································································306.4回路电阻测量·······················································································································306.5温升试验·······························································································································306.6短时和峰值耐受电流试验···································································································316.7开断能力和关合能力试验···································································································316.8机械试验·······························································································································326.9辅助回路和运动部分防护等级验证···················································································326.10外壳强度试验·····················································································································326.11防雨试验·····························································································································336.12内部故障电弧试验·············································································································336.13极限温度下机械操作试验·································································································346.14气体密封性试验·················································································································346.15噪音测量·····························································································································346.16断路器·································································································································356.17隔离开关·····························································································································366.18构成GIS的其他主要元件·································································································377出厂试验··········································································································································377.1主回路绝缘试验···················································································································387.2辅助回路绝缘试验···············································································································387.3主回路电阻测量.··················································································································387.4局部放电试验·······················································································································387.5外壳压力试验·······················································································································387.5气体密封性试验···················································································································387.7机械试验·······························································································································387.8电气、气动和其他的辅助装置试验···················································································397.9接线检查·······························································································································397.10六氟化硫气体的水分含量测定·························································································397.11断路器出厂试验项目·········································································································397.12隔离开关出厂试验项目·····································································································407.13构成GIS的其他主要元件·································································································408现场交接试验··································································································································408.1GIS现场交接试验项目包括:····························································································408.2外观检查·······························································································································418.3主回路电阻测量···················································································································418.4元件试验·······························································································································418.5SF6气体的验收······················································································································428.6气体密封性试验···················································································································428.7SF6气体湿度测量··················································································································428.8主回路绝缘试验···················································································································438.9局部放电测量·······················································································································438.10辅助回路的绝缘试验·········································································································448.11联锁试验·····························································································································448.12气体密度装置及压力表校验·····························································································44II GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.9备品备件及专用工器具··················································································································449.1备品备件·······························································································································449.2专用工器具···························································································································4410GIS的选用导则······························································································································4511查询和订货时提供的资料············································································································4511.1系统的特征·························································································································4511.2工作条件·····························································································································4511.3设备及其元件的特征·········································································································4511.4操动机构的特征·················································································································4612投标时提供的资料························································································································4612.1额定值和特征·····················································································································4612.2设备及其元件的更详细情况·····························································································4612.3型式试验证书或报告·········································································································4712.4结构特征·····························································································································4712.5操动机构的特征·················································································································4712.6有关需经制造厂和用户预先协商的所有事项的资料·····················································4712.7推荐的备件、专用工具和试验用附件清单·····································································4712.8运行和维护的说明。·········································································································4713运输、贮存、安装、运行和维护································································································4713.1运输、贮存和安装的条件·································································································4713.2安装·····································································································································4813.3维护·····································································································································4813.4运行·····································································································································48气体绝缘金属封闭开关设备技术标准编制说明··············································································49III GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.气体绝缘金属封闭开关设备技术标准1总则1.1为适应电网的发展要求,提高设备运行的安全可靠性,加强输变电设备技术管理,特制定本技术标准。1.2本标准是依据国家和国际的有关标准、规程和规范,并结合近年来国家电网公司输变电设备评估分析、生产运行情况分析以及设备运行经验而制定的。1.3本标准对气体绝缘金属封闭开关设备的设计选型(运行选用)、订货、监造、出厂验收、包装运输、现场安装和现场验收等环节提出了具体的技术要求。1.4本标准适用于全部或部分地采用气体作为绝缘介质的气体绝缘金属封闭开关设备。标准中的术语“GIS(gas-insulatedmetal-enclosedswitchgear)”系指“气体绝缘金属封闭开关设备”,即:由若干相互直接联结在一起的单独元件构成的,且只有在这种方式下才能运行。除本标准另有规定外,各元件应符合各自的技术规范。(电压等级?)1.5各网省公司在编制设备技术参数和要求时可根据本标准,结合本地区实际情况增补相应的内容。1.6引用文件以下为输电设备设计、制造及试验所应遵循的国家、行业和企业的标准及规范,但不仅限于此:GB/T13540高压开关设备抗地震性能试验GB/T5582高压电力设备外绝缘污秽等级GB311.1—1997高压输变电设备的绝缘配合GB311.7高压输变电设备的绝缘配合使用导则GBl984—1989交流高压断路器GBl985—1989交流高压隔离开关和接地开关GB/T2900.20电工术语高压开关设备GB3309—1989高压开关设备常温下的机械试验GB4109—1988高压套管技术条件GB4208—1993外壳防护等级(1P代码)GB7354—1987局部放电测量GB8905—1988六氟化硫电气设备中气体管理和检测导则GB11022—1989高压开关设备通用技术条件1 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.GB11023—1989高压开关设备六氟化硫气体密封试验导则GB12022工业六氟化硫GB7674-199772.5kV及以上气体绝缘金属封闭开关设备DL/T486-2000交流高压隔离开关订货技术条件DL/T618-1997气体绝缘金属封闭开关设备现场交接试验规程DL/T728-2000气体绝缘金属封闭开关设备订货技术导则DL/T593-1996高压开关设备和控制设备的公用技术要求国家电网公司电力生产设备评估管理办法(生产输电[2003]95号)国家电网公司关于加强电力生产技术监督工作意见(生产输电[2003]29号)国家电网公司预防交流高压断路器事故措施(国家电网生[2004]641号)IEC60859额定电压72.5kV及以上GIS的电缆连接2使用条件2.1正常使用条件GIS分为户内型和户外型。对于GIS大部分元件装于户内,仅进出线部分装于户外,除装在户外部分应满足户外使用条件外,其余按户内使用条件。除非另有规定,GIS在其额定特性和正常使用条件下使用。如果使用条件和正常使用条件不同,制造厂应尽可能按用户提出的特殊要求设计产品,或者应与用户达成适当的协议(见2.2)。2.1.1户内GIS设备a)周围空气温度最高不超过40℃,且在24h内测得的平均温度不超过35℃。周围空气最低温度对“-5户内”级为-5℃,对“-15户内”级为-15℃,对“-25户内”级为-25℃。b)阳光辐射的影响可以忽略。c)周围空气没有明显地受到尘埃、烟、腐蚀性和/或可燃性气体、蒸汽或盐雾的污染。d)湿度条件如下:――在24h内测得的相对湿度的平均值不超过95%;――在24h内测得的水蒸气压力的平均值不超过2.2kPa;――月相对湿度平均值不超过90%;――月水蒸气压力平均值不超过1.8kPa。在这样的湿度条件下有时会出现凝露。注:1高湿度期间,温度发生急降时会出现凝露;2为耐受湿度和凝露所产生的效应,用户应采用按此条件设计和进行过试验的断路器产品;2 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.3若不采用按2中要求的条件设计和进行过试验的断路器产品,也可采用特殊设计的建筑物或小室,用适当的通风、加热或除湿装置防止产生凝露。e)来自设备外部的振动或地动可以忽略。f)在二次系统的接口上感应的电磁干扰对于正常的EMC严酷等级,共模电压不超过1.6kV;对于降低的EMC严酷等级,共模电压不超过0.8kV。注:互感器接口上的最大感应电压可能超过上述数值,其性能应参照互感器的标准。2.1.2户外GIS设备a)周围空气温度最高不超过40℃,且在24h内测得的平均温度不超过35℃。周围空气最低温度对“-10户外”级为-10℃,对“-25户外”级为-25℃,对“-40户外”级为-40℃。应考虑温度的急骤变化。b)应考虑阳光辐射的影响,晴天中午的辐射强度为1000W/㎡。注:1在一定的阳光辐射条件下,为使温升不超过规定值,必要时应采取适当措施,如加盖遮阳顶、强迫通风散热等,或者降容运行。2阳光辐射的详细资料见GB4797.4。c)海拔不超过1000m。d)周围空气可能存在尘埃、烟、腐蚀性和/或可燃性气体、蒸汽或盐雾的污染,其污秽等级不超过GB/T5582中规定的Ⅱ级。e)覆冰厚度对1级不超过1㎜,对10级不超过10㎜,对20级不超过20㎜。f)风速不超过34m/s。g)应考虑凝露和降水的影响。h)来自设备外部的振动或地动可以忽略。i)在二次系统的接口上感应的电磁干扰对于正常的EMC严酷等级,共模电压不超过1.6kV;对于降低的EMC严酷等级,共模电压不超过0.8kV。注:互感器接口上的最大感应电压可能超过上述数值,其性能应参照互感器的标准。2.2特殊使用条件断路器设备可以在不同于2.1中规定的正常使用条件下使用,这些特殊要求应参照下述的特殊使用条件提出。2.2.1海拔在任何海拔下,GIS内绝缘的绝缘特性和海平面上测得的相同。因而,对这种绝缘不提出海拔方面的要求。但对于GIS采用户外充气套管型式(进、出线),则应提出具体要求,并按下列给出方式进行计算:3 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.对于使用在海拔高于1000m处的设备,其外绝缘在标准参考大气条件下的绝缘水平是将使用场所要求的绝缘耐受电压乘以海拔修正系数Ka,系数Ka按图1选取。注1:在任一海拔处,内绝缘的绝缘特性是相同的,不需要采取特别的措施。注2:对于低压辅助设备和控制设备,如海拔低于2000m,不需采取特别措施。如用于海拔高于2000m以上的地方,见GB16935.1。这些系数可按GB311.7的规定按下式计算:m(H-1000)/8150Ka=e式中:H为海拔,以m为单位;m=1对于工频、雷电冲击和相间操作冲击电压;m=0.9对于纵绝缘操作冲击电压;m=0.75对于相对地操作冲击电压。ka1.501.40m=1m=0.91.30m=0.751.201.101.001000150020002500300035004000H图1海拔修正系数Ka2.2.2污秽对于使用在重污秽空气中的设备,污秽等级应规定为GB/T5582中的Ⅲ级――重污秽,或Ⅳ级――严重污秽。4 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.2.2.3温度和湿度对于使用在周围空气温度超出2.1中规定的温度范围的设备,应有限选用的最低和最高温度的范围规定为:―对严寒气候:-50℃至+40℃;―对酷热气候:-25℃至+50℃。在暖湿风频繁出现的某些地区,温度的骤变会导致凝露,甚至户内也会产生凝露。在湿热带户内条件下,在24h内测得的相对湿度的平均值能达到98%。2.2.4振动在可能发生地震的地区,应按GB/T13540的规定提出设备的抗震等级。一般按设防。2.2.5其它参数设备在其它特殊使用条件下使用时,应参照GB/T4796、GB/T4797、GB/T4798的规定提出其环境参数。3术语和定义GB7674-1997的第3章适用。4技术要求a)额定电压;b)额定绝缘水平;c)额定频率;d)额定电流;e)额定短时耐受电流(主回路的和接地回路的);f)额定峰值耐受电流(主回路的和接地回路的);g)额定短路持续时间;h)GIS的元件(包括它们的操动机构和辅助设备)的额定值;i)用作绝缘的气体的额定密度和最小运行密度。4.1额定电压额定电压表示GIS所在系统的最高电压,即电气设备的最高电压。72.5,126,252,363,550,800kV。注:G1S中的元件可按有关的标准具有各自的额定电压值。4.2额定绝缘水平GIS的额定绝缘水平应从表1和表2中选取。5 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.表172.5,126,252kVGIS的额定绝缘水平(kV)额定电压额定短时工频耐受电压(有效值)额定雷电冲击耐受电压(峰值)(有效值)相对地、相间隔离断口相对地、相间隔离断口(1)(4)(5)(2)(3)14616032537572.5160176350385185210450520126230265550630360415850950252395460950105046053010501200注l:根据我国电力系统的实际,本表中的额定绝缘水平与IEC60694略有不同。注2:本表中括号内的数值为中性点接地系统使用的数值,项(2)和项(3)括号内的数值亦为湿试时的数值;项(2)和项(4)的数值取自GB311.1表3和表4。注3:隔离断口是指隔离开关、负荷-隔离开关和起联络作用的断路器或负荷开关的断口。表2363,550,800kVGIS的额定绝缘水平(kV)额定短时工频耐受电压额定操作冲击耐受电压额定雷电冲击耐受电压额定电压(有效值)(峰值)(峰值)(有效相对地、隔离相对地、值)相对地相间隔离断口隔离断口相间断口相间(1)(2)(3)(4)(5)(6)(7)8)l050(+207)4605208501300800(+296)1050+296363l175(+207)5105809501425850(+296)1175+2961425(+315)63074010501675900(+450)1425+4501550(+315)550680790l17518001050(+450)1550+4501675(+315)7408301675+4501800(+455)130022101800+65080083011501100(+650)2100(+455)142524202100+650注:l本表中的额定绝缘水平与IEC60694略有不同。2本表中800kV的额定绝缘水平取自IEC60694表2a。3本表中363kV和550kV的项(2)、项(4)、项(5)、项(6)、项(7)、项(8)取自GB311.1表2。4项(6)和项(8)中之数值是加在同一级另一端子上的反极性工频电压峰值。项(6)括号中的数值为1.0√2U/√3,项(8)中括号内的数值一为0.7√2U/√3(U为额定电压),另一为1.0√2U/√3,用户可根据需要取则。6 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.表1和表2中的额定耐受电压值适用于标准参考大气条件(温度、压力和湿度)。使用条件偏离标准参考大气条件时,外绝缘的试验电压应按DL/593-200X的有关规定予以修正。雷电冲击电压,操作冲击电压(采用时)和短时工频电压耐受试验的额定耐受电压应在表中同一行内选取。同一额定电压有几个绝缘水平可供选择时,用户应根据绝缘配合研究的结果,并在研究中计及GIS自身开合产生的瞬态过电压的影响,来选取适当的绝缘水平。GIS包括具有确定的绝缘水平的各种元件。虽然选择适当的绝缘水平能大大避免内部故障,但仍应考虑限制外部过电压的措施(避雷器、保护火花间隙)。注1:对于套管(如有时)的外绝缘,其额定绝缘水平应符合本标准5.2的规定。注2:在尚未得出GIS对其他冲击波形的耐受能力的研究结论之前,按雷电冲击波形和操作冲击波形考虑。4.3额定频率额定频率是50Hz。4.4额定电流与温升4.4.1额定电流优先从下列数值中选取:630,800,1000,1250,l600,2000,2500,3150,4000,5000,6300A。注:GIS的主回路(例如母线、支线等)可具有不同的额定电流值。4.4.2温升对于不受DL/T593限制的元件(如电流互感器、电压互感器等),其温升不得超过这些元件各自技术标准的规定。GIS外壳的允许温升见表3。表4-3外壳的允许温升外壳部位周围空气温度为40℃时的允许温升(K)运行人员易触及的部位30运行人员可触及但在正常操作时不需触及的部位401)运行人员不可触及的部位65注1:对温升超过40K的部位,应作出明显的高温标记,以防维修人员触及,并应保证不损害周围的绝缘材料和密封材料。4.5额定短时耐受电流优先从下列数值中选取:25kA,31.5kA,40kA,50kA,63kA,80,100kA。注:原则上,主回路的额定短时耐受电流不能超过其中串联的最薄弱元件的相应额定值。7 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.4.6额定峰值耐受电流额定峰值耐受电流等于2.5倍额定短时耐受电流。注1:原则上,主回路的额定峰值耐受电流不能超过其中串联的最薄弱元件的相应额定值。注2:用户有不同要求时可与制造厂协商。4.7额定短路持续时间550kV~800kVGIS的额定短路持续时间为2s。252kV~363kVGIS的额定短路持续时间为3s。126kV及以下GIS的额定短路持续时间为4s。4.8断路器及隔离开关4.8.1断路器包括下列额定值,选取数值参见国家电网公司《交流高压断路器技术规范》:1)额定电压2)额定频率3)额定绝缘水平4)额定电流和温升5)额定短时耐受电流6)额定短路持续时间7)额定峰值耐受电流8)额定短路开断电流9)关于额定短路电流开断次数的规定10)关于断路器机械寿命的规定11)额定短路关合电流12)额定瞬态恢复电压(出线端故障)13)额定操作顺序14)额定近区故障特性15)额定失步开断电流16)额定线路充电开断电流17)额定电缆充电开断电流18)额定单个电容器组开断电流19)额定背对背电容器组开断电流8 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.20)额定单个电容器组关合涌流21)额定背对背电容器组关合涌流22)额定小感性开断电流23)额定时间参量24)操动机构、控制回路及辅助回路的额定电源电压25)操动机构、控制回路及辅助回路的额定电源频率26)操作和灭弧用压缩气体源的额定压力27)额定异相接地的开合试验28)噪声及无线电干扰水平29)断口并联电容器参量:30)合闸电阻参量:4.8.2隔离开关和接地开关包括下列额定值,选取数值参见国家电网公司《交流高压隔离开关和接地开关技术规范》:1)额定电压(Ur)2)额定绝缘水平3)额定频率(fr)4)额定电流(Ir)5)额定短时耐受电流(Ik)6)额定峰值耐受电流(Ip)7)额定短路持续时间(tk)8)分闸、合闸装置和辅助回路的额定电源电压(Ua)9)分闸、合闸装置和辅助回路的额定电源频率10)绝缘和/或操作用压缩气源的额定压力11)额定短路关合电流(仅对接地开关);而且,对额定电压72.5kV及以上隔离开关和接地开关要求:12)额定母线转换电流开合能力(隔离开关);13)额定感应电流开合能力(接地开关)。4.8.3快速接地开关除具备接地开关的额定值,还包括:1)时间参数:分、合闸时间上、下限,合闸时间应不超过0.1s;分、合闸速度应能保证其开断及关合性能。2)开断和关合能力。额定关合短路电流应与断路器一致,关合次数为2次。3)操动机构:型式分电动弹簧、气动、手动储能弹簧或其他。9 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.4.9其他设备互感器设备和避雷器,额定值及数值选取参见国家电网公司相应设备技术规范。4.10母线1)导体的电感、电容、电阻及波阻抗由制造厂提供。2)外壳电阻由制造厂提供。3)母线的导体和外壳的电能损耗(W/m)由制造厂提供。4.11绝缘子1)1.1倍额定相电压下局部放电量应不大于3pC。2)盆式绝缘子破坏压力与其运行压力之比,即安全系数大于4.5。3)1.1倍额定相电压下,最大电场强度不大于1.5kV/mm。4.12操动机构4.12.1操作机构和辅助回路的额定电源电压和频率从下列数值中选取:直流:24V,48V,110V,220V;交流(50Hz):单相220V,三相380V。4.12.2操动机构用压缩空气源的额定压力从下列数值中选取:0.5MPa,1.0MPa,1.6MPa,2.0MPa。如有需要,可选用其他数值。压缩空气源的压力为操作前贮气罐内气体的压力。4.13用作绝缘的气体的额定密度和最小运行密度GIS在绝缘气体的额定密度下运行,该额定密度由制造厂选定。绝缘气体的最小运行密度由制造厂规定,低于此密度值,GIS与此有关的额定值不能保证。GIS中的绝缘气体,可有几个额定密度及与其相应的几个最小运行密度。各隔室之间可以不同。注:绝缘气体的额定密度和最小运行密度可用(定体积下)相应的压力—温度曲线或用20℃时相应的压力来表示5设计和结构5.1一般要求GIS应设计成能安全地进行下述各项工作:正常运行、检查和维修、引出电缆的接地、电缆故障的定位、引出电缆或其他设备的绝缘试验、消除危险的静电电荷、安装或扩建后的相序校10 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.核和操作联锁等。GIS的设计,应使协议允许的基础位移或热胀冷缩的热效应不致影响其保证的性能。额定值及结构相同的所有可能要更换的元件应具有互换性。除本标准另有规定外,装在外壳中的各种元件应遵循它们各自的标准。5.2对GIS中六氟化疏气体的要求新六氟化硫气体的质量标准应符合表4的规定;表4新六氟化硫气体的质量标准项目名称GB12022标准规定值纯度(SF6)(m/m)≥99.8%空气(N2+O2或Air)(m/m)≤O.05%四氟化碳(CF4)(m/m)≤0.05%湿度(H2O)≤8■g/g酸度(以HF计)≤O.3■g/g可水解氟化物(以HF计)≤1.0■g/g矿物油≤10■g/g毒性生物试验无毒GIS中六氟化硫气体的水分含量规定在表5中给出。表5GIS中六氟化硫气体的水分含量标准隔室有电弧分解物的隔室(■l/l)无电弧分解物的隔室(■l/l)交接验收值≤150≤250运行允许值≤300≤5005.3支撑、底架及接地5.3.1支撑GIS按运输拼装单元设置独立的支撑底架,并设置和标明起吊部位、在运输中需要拆除的部位,必要时应增设运输临时支撑。GIS的支撑底架结构若为固定不可调整式,制造厂在出厂前应予调整使符合现场安装要求,在现场安装时不得再用垫块调整。电缆终端支撑底架应满足电缆现场施工的方便及电缆的固定。GIS的所有支撑不得妨碍正常维修巡视通道的畅通。5.3.2接地制造厂在提供的GIS平面布置图或基础图上,应标明与接地网连接的具体位置及连接的结11 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.构。GIS的接地连线材质应为电解铜,并标明与地网连接处接地线的截面积要求。当采用单相一壳式钢外壳结构时,应采用多点接地方式,并确保外壳中感应电流的流通以降低外壳中的涡流损耗。接地开关与快速接地开关的接地端子应与外壳绝缘后再接地,以便测量回路电阻,校验电流互感器变比,检测电缆故障。G1S设备的每个间隔底架上均应设置可靠的适合于规定故障条件的接地端子,该端子应有一紧固螺钉或螺栓用来连接接地导体。紧固螺钉或螺栓的直径应不小于12mm。接地连接点应标以GB/T5465.2规定的“保护接地”符号。和接地系统连接的设备的金属外壳部分可以看作是接地导体。5.3.2.1主回路接地。为保证维修工作的安全,主回路应能接地。另外,在外壳打开以后的维修期间,应能将主回路连接到接地极。接地可用以下方式实现a)如不能预先确定回路不带电,应采用关合能力等于相应的额定峰值耐受电流的接地开关;b)如能预先确定回路不带电,可采用不具有关合能力或关合能力低于相应的额定峰值耐受电流的接地开关;c)仅在制造厂和用户取得协议的情况下,才能采用可移的接地装置。5.3.2.2外壳应接地。凡不属于主回路或辅助回路的且需要接地的所有金属部分都应接地。外壳、构架等的相互电气联接宜用紧固联接,以保证电气上连通。为保证接地回路可靠连通,应考虑到可能通过的电流所产生的热和电的效应。注:其它涉及接地的要求,如外壳的感应电压值等,在GIS的供货技术协议中提出。5.4控制和辅助设备5.4.1一般要求(1)外壳。辅助和控制回路的外壳应由能够耐受机械、电气和热的应力,以及能耐受在正常运行条件下可能出现的湿度效应的材料组成。操动机构箱和开关箱均应能防寒、防热、防潮、放水、防尘和防止异物进入。外壳应通过采用防腐材料或者对暴露的表面采用适当的防腐涂层来取得良好的防腐性能。辅助和控制回路的外壳提供的防护等级应符合6.9.3的规定。电缆入口处的门、盖板等应设计成在电缆正确安装后能达到外壳的防护等级。所有通风口的门应予以屏蔽活着其布置能达到为外壳规定的相同的防护等级。(2)电击防护。安装在GIS框架上的辅助和控制设备应对来自于主回路的破坏性放电予12 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.以防护。辅助和控制回路的接线,除了互感器、脱扣线圈、辅助触头等端子上长度较短的电线以外,应通过接地的金属隔板(例如金属管)或者绝缘材料制成的隔板(例如绝缘管)与主回路隔离。运行中,应注意辅助和控制回路能够被触及但不会直接接触高压部件的危险。对于需要考虑因异常的环境条件(例如雪、沙等的集聚)而导致安全性能降低的场合,则应提高其上的带电部件的最低高度。(3)火灾危害。由于辅助和控制回路中存在火灾的危险,在正常使用条件下以及即使在可预见的异常使用条件下发生误动作和故障时,均应减低火灾的可能性。第一目标是防止带电部件产生火花。如果火灾或火花发生在外壳内部,第二目标是限制火灾的危害。制造厂要通过合理的回路设计和保护使得内部故障和过载条件下不会增加火灾危害。制造厂应设计或选取额定容量值高于正常运行条件下所需要的额定值的元件,且其自燃特性应根据回路的最大故障容量决定。应特别注意电阻器。应对元件的总装和这些元件的相对布置予以考虑,通过在他们周围提供足够的的空间来散发过多的热量。为了控制火灾的冲击,应采取预防措施。使用的材料应足以耐受可能的燃烧和内部的热源。应尽可能采用具有阻燃性能的材料。5.4.2辅助和控制回路元件的要求(1)元件的选择。GIS设备中辅助和控制回路元件包括:辅助开关、继电器、并联脱扣器、电动机、加热元件、表计、计数器、指示灯、电缆和电线、端子、辅助和控制触头、辅助和控制触头以外的触头、接触器和电动机启动器、低压开关、低压断路器、低压熔断器、低压隔离开关、插头、插座和接线器、印刷板、电阻器、照明、线圈等。这些元件应满足相关的国家和行业标准的要求及DL/T593中5.4.4条的规定。如果没有相关的国家和行业标准,或者元件是按照另外的标准(如由某个国家或组织发布的标准)经过试验的,则选取的判据应在制造厂和用户之间达成协议。辅助和控制回路中使用的所有元件的选择和设计应使得在所有实际运行条件下、在辅助和控制回路的外壳内,能够在其额定特性下运行。应当采取适当的措施(隔热、加热、通风等)保证维持正确功能所需要的运行条件。如果加热是设备正确功能的基本条件,应提供对加热回路的监控。对于用于低温地区的断路器,其机构箱中应设置可自动投切的加热装置,并有保温措施。加热器在额定电压下的损耗应在制造厂规定值的±10%范围内。对于户外GIS,应进行适当的布置(通风和/或内部加热等)以防止辅助和控制回路外壳内产生有害的凝露。13 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.连接点上极性的反转不应该损坏辅助和控制回路。(2)元件的安装。元件应按照其制造厂的说明书进行安装。(3)可触及性。分闸和合闸执行器以及紧急关闭系统的执行器应位于正常的操作高度以上0.4m到2m之间。其它执行器应位于易被操作的高度,指示装置应位于易被读取的位置。考虑到正常操作高度,构架安装和地面安装的辅助和控制回路的外壳应安装在高度满足上述可触及性、操作和读取高度要求的位置。外壳内元件的布置应使得在安装、接线、维护和更换时能够触及的位置。(4)识别。安装在外壳内的元件应易于识别,且应该和接线图和电路图的指示一致。如果元件是插入式的,则元件和固定部分(元件插入的位置)上应有确认标记。在元件或电压的混杂可能引起混乱的场合,应考虑更明晰的标记。5.5动力合闸用外部能源操作的设备(如:断路器或隔离开关),当操动机构的动力源的电压或压力处在规定值的下限时,应该能关合和/或开断它的额定短路电流。如果制造厂规定了最大合闸和分闸时间,在电压或压力处在规定值的下限时,所测得的分闸和合闸时间不得超过此值。动力式操作机构应有供检修及调整用的手力合闸装置和手力脱扣装置或就地操作按钮。除了在维修时的慢操作外,主触头只应该在传动机构的作用下以设计的方式运动。当合闸装置和/或分闸装置失去能源或失去后重新施加能源时,不应该引起主触头合闸或分闸位置的改变。动力式操动机构,当操作能源的电压、压力在表6规定的范围内时,应保证设备可靠合闸(包括关合额定短路关合电流),且关合后应能接着立即开断;在规定的最高值时,应能空载合闸而不产生异常现象。表6操作能源的电压和压力操作能源参数额定短路关合电流电压气压或液压(峰值)kA直流交流<5080%~110%额定电压85%~110%额定电压85%~110%额定压力≥5085%~110%额定电压14 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.注1:表中规定的电压极限范围为受电元件线圈通电时端钮间的稳态数值。注2:表中规定的气压(液压)极限范围为操动机构附有的储气(压)筒内的气(液)压数值。注3:表中规定的电压极限范围只有当电磁式或电动机式操动机构的电磁合闸线圈或电动机绕组的温度不超过80℃时方有效。注4:对气动、弹簧和液压操作机构的合闸线圈的动作要求与5.7的要求相同。注5:电磁机构的合闸接触器的动作电压要求与5.7的要求相同。5.6贮能合闸储能操作的设备(如:断路器或隔离开关),当操动机构储足能量时,应该能关合和开断它的额定短路电流,在规定的相应最低气压或液压下能满意地进行各种恰当的操作。如果制造厂规定了最大合闸和分闸时间,所测得的分闸和合闸时间不得超过此值。对具有单独的泵或压缩机的的设备(如:断路器或隔离开关),泵或压缩机的出力、储气罐或液压蓄能器的容量应足以供给设备在额定短路关合和开断电流及以下的所有电流下进行额定操作顺序的操作。操作顺序开始时的压力应等于制造厂按照上述要求以及泵或压缩机得以正常运转所规定的适当的最低压力。除了在维修时的慢操作外,主触头只应该在传动机构的作用下以设计的方式运动。当合闸装置和/或分闸装置失去能源或失去后重新施加能源时,不应该引起主触头合闸或分闸位置的改变,即操动机构应该有防止失压慢分或失压后重新打压慢分的功能。供弹簧储能的或驱动压缩机或泵的电动机及其电气辅助设备,在额定电源电压的85%到110%之间,在额定频率下,应该能够正常工作。储能操作的的设备(如:断路器或隔离开关),应能在关合额定短路关合电流的操作后立即分闸。5.7脱扣器操作脱扣器的操作极限值应符合以下规定:5.7.1并联合闸脱扣器并联合闸脱扣器在合闸装置的额定电源电压的80~110%范围内、交流时在合闸装置的额定电源频率下,应能可靠动作。当电源电压等于或小于额定电源电压的30%时,并联合闸脱扣器不应动作。5.7.2并联分闸脱扣器并联分闸脱扣器在分闸装置的额定电源电压的65~110%(直流)或80~110%(交流)范围内、交流时在分闸装置的额定电源频率下,在断路器装置所有的直到其额定短路开断电流的操作条件下,均应能可靠动作。15 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.当电源电压等于或小于额定电源电压的30%时,并联分闸脱扣器不应动作。5.7.3并联脱扣器的电容储能操作采用由主回路通过与设备(如:断路器或隔离开关)装置组成一体的整流器――电容器组对电容器充电而作为并联脱扣器的操作能源时,当主回路电源与整流器――电容器组的端子断开、并用导线短接放电5s后,电容器上保留的电荷应该足以使脱扣器可靠动作。断开前主回路的电压应取与断路器设备额定电压相应的系统最低电压。5.7.4欠压脱扣器当欠压脱扣器端子电压降到其额定电压的35%以下时,欠压脱扣器应该动作使断路器分闸。当欠压脱扣器端子电压大于其额定电压的65%时,它不应动作。当欠压脱扣器端子电压等于或大于其额定电压的85%时,断路器应能合闸;当端子电压低于其额定电压的35%时,断路器不能合闸。5.7.5附装的失压脱扣器附装的失压脱扣器的动作特性应符合表7的规定。某些机构的失压脱扣器应具有延时脱扣的性能。在预定的延时终了前,若电压恢复到某一值,则脱扣器不得完成其动作,并返回到初始位置,制造厂应给出有关说明。表7失压脱扣器的动作特性电源电源与额定电源电压的<30%35~65%65~85%>85%比值失压脱扣器的工作状态铁心应可靠地释放铁心允许释放铁心不得释放铁心应可靠地吸持5.7.6附装的过电流脱扣器附装的过电流脱扣器的额定电流规定为5A,脱扣电流等级及其准确度应符合表8的规定。表8过电流脱扣器脱扣电流等级及其准确度过电流脱扣器种类瞬时动作的不定限延时的定限延时的脱扣电流A5~155~105~10美级脱扣电流的准确度±10%同一脱扣器终各级脱扣电流准确度的差异±5%过电流延时脱扣器的延时应能调整,其延时最大值应不小于1s;当整定值为0s时,脱扣器的动作时间应不大于0.1s。在特性曲线上与电流无关的部分,定限延时脱扣器的延时准确度应不超过±0.5s;定限延时脱扣器的延时准确度在特性曲线上与电流有关的部分,以及不定限延时脱扣器的延时准确度不规定其标准数值。16 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.定限延时脱扣器的特性曲线与电流无关的部分的起点,应落在脱扣电流值的250%~350%的范围内。由电流互感器供电的附装过电流脱扣电磁铁,当其电路依靠分装的过电流继电器触点的动作关合时,其脱扣电流应为2.5A及以上。5.5.7多个脱扣器对于72.5kV及以上的设备(如:断路器)应设计两个相互独立的分闸回路和脱扣器。当装有同样功能的、分别作用的多个脱扣器时,任一个脱扣器的缺陷不应影响其它脱扣器的正常功能。5.8气体监测系统及气体压力闭锁装置每个封闭压力系统(隔室)应设置密度监视装置,制造厂应给出补气报警密度值,对断路器室还应给出闭锁断路器分、合闸的密度值。低气(液)压和高气(液)压闭锁装置应整定在制造厂指明的合适的压力极限上(或内)动作。密度监视装置可以是密度表,也可以是密度继电器。压力(或密度)监视装置应装在与本体环境温度一致的位置,并设置运行中可更换密度表(密度继电器)的自封接头或阀门。在此部位还应设置抽真空及充气的自封接头或阀门,并带有封盖。当选用密度继电器时,还应设置真空压力表及气体温度压力曲线铭牌,在曲线上应标明气体额定值、补气值曲线。在断路器隔室曲线图上还应标有闭锁值曲线。各曲线应用不同颜色表示。密度监视装置可以按GIS的间隔集中布置,也可以分散在各隔室附近。当采用集中布置时,管道直径要足够大,以提高抽真空的效率及真空极限。密度监视装置、压力表。自封接头或阀门及管道均应有可靠的固定措施。应防止内部故障短路电流发生时在气体监视系统上可能产生的分流现象。气体监视系统的接头密封工艺结构应与GIS的主件密封工艺结构一致。5.9铭牌GIS及其主要元件和高压开关的操动机构应具有耐久和清晰易读的铭牌。断路器等设备及其操动机构的铭牌要求见国家电网公司相关设备技术规范。铭牌应标有设备技术规范中规定的必要的信息,铭牌应在正常工作位置和安装位置均可见。如果断路器设备由带有操动机构的几个单极组成,则每个单极均应装设铭牌。对与断路器组成一体的操动机构,可以只用一个组合的铭牌。对于户外GIS,铭牌应能耐受气候环境影响。应提供其SF6气体压力与温度的关系曲线。操动机构的线圈应有参考标牌,使之能从制造17 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.厂获得全部数据。脱扣器也应带有适当的参数。当GIS装有套管型电流互感器时,应在断路器的铭牌上或其它补充铭牌上标出电流互感器各分接头的变流比、准确度、容量;断路器装有电压抽取装置时,应有一个补充铭牌标明二次电压的数据。GIS的铭牌应包含如下内容:a)制造厂名称或商标;b)型号或系列号;c)采用标准的编号;并建议给出下列数据:d)额定电压;e)母线和支线的额定电流;f)额定频率;g)额定短时耐受电流;h)用作绝缘的气体的额定密度或压力(20C时);i)用作绝缘的气体的最小运行密度或压力(20C时);j)外壳设计压力。如GIS的共用数据已在其铭牌上作了说明,则各元件的铭牌可以简化。5.10防护等级所有控制和/或辅助回路及操动机构的外壳,均应按照GB4208规定其防护等级。防护等级应适用于设备的使用条件。5.10.1防止人体接近危险部件的防护和防止固体外物进入设备的防护外壳对人体提供的防止接近主回路、控制和/或辅助回路的危险部件以及任何危险的运动部件的防护等级,应用表9中规定的IP标志的符号表示。IP标志的第一位特性数字表示外壳对人体提供的防护等级以及防止固体外物进入设备外壳内部防护等级。如果只要求防止接近危险部件的防护,或者要求的防护比第一位特征数字表示的要高,可以使用一个附加的字母,如表9所示。表9防护等级防护等级防止固体异物进入防止接近危险部件IP1XB直径50㎜及以上的物体防止手指接近(直径12㎜长80㎜的试指)IP2X直径12.5㎜及以上的物体防止手指接近(直径12㎜长80㎜的试指)IP2XC直径12.5㎜及以上的物体防止工具接近(直径2.5㎜长100㎜的试棒)18 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.IP2XD直径12.5㎜及以上的物体防止导线接近(直径1.0㎜长100㎜的试验导线)IP3X直径2.5㎜及以上的物体防止工具接近(直径2.5㎜长100㎜的试棒)IP3XD直径2.5㎜及以上的物体防止导线接近(直径1.0㎜长100㎜的试验导线)IP4X直径1.0㎜及以上的物体防止导线接近(直径1.0㎜长100㎜的试验导线)尘埃不能完全防止尘埃进入,但尘IP5X防止导线接近(直径1.0㎜长100㎜的试验导线)埃的进入量和位置不得影响设备的正常运行或危及安全注1:表示防护等级的符号符合GB4208。注2:对IP5X,GB4208的12.4的类别2是适用的。注3:如果只关心防止接近危险部件的防护,则使用附加字母并把第一位特性数字用X代替。5.10.2防止水浸入的防护IP标志的第二位特性数字表示防止有害的水浸入,这一防护不规定等级(第二位特征数字X)。对于有防雨和防其它气候条件的附加防护性能要求的户外设备,应该在第二位特征数字后或在附加的字母后用补充字母W说明。5.10.3在正常使用条件防止设备受到机械撞击的保护GIS设备的操动机构箱、端子箱、二次汇控柜的外壳应有足够的机械强度。对户内GIS设备的操作机构箱、端子箱、二次汇控柜的外壳推荐的撞击能量为2J。1.1.1.5.10.4对没有附加的机械防护的户外GIS设备的操动机构箱、端子箱、二次汇控柜的外壳,由制造厂与用户协商,可以规定较高的撞击能量。断路器、隔离开关、接地开关等操动机构箱、端子箱、二次汇控柜,应防尘和防止异物进入,防护等级为户内IP40/户外IP54。底部的电缆引入孔,应有利于电缆的固定及封堵。5.10.5主回路的防护等级主回路和直接与其相连的部件的防护等级不作规定。5.11内部故障5.11.1概述GIS在结构布置上应使内部故障电弧对其继续工作能力的影响降至最小。电弧效应限制在起弧的隔室或故障段的另一些隔室(若该段的隔室之间有压力释放措施时)之内,事故后,余下的设备应具有继续正常工作的能力。GIS发生内部故障的概率很低。通常还可采取一系列的措施来避免内部故障引起电弧及限制19 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.电弧持续的时间和产生的后果。尽管这样,如制造厂和用户之间达成协议,要验证内部故障引起的电弧效应,则按本标准第7.11条进行试验。当单相-壳式的GIS用于中性点非有效接地系统,并装有限制内部接地故障持续时间的保护装置的情况下,一般不需做此试验。5.11.2电弧的外部效应为了对人身提供可靠的保护,应采取适当的保护措施使电弧的外部效应限于外壳出现穿孔或开裂而无任何碎裂。制造厂应提供关于所用的保护措施方面的充足资料。制造厂和用户可商定一个允许的内部故障电弧持续时间。在此时间内,当短路电流不超过某一数值时,将不发生电弧的外部效应。5.11.3内部故障定位如用户要求,制造厂应就故障定位的方法提出合适的建议。5.12外壳5.12.1概述外壳可以是钢板焊接、铝合金板焊接结构或铸铝结构。外壳应牢固地接地并能承受运行中出现的正常和瞬时压力,并按压力容器有关标准设计、制造与检验。对户外GIS,应考虑气候条件(见本标准第3章)的影响。5.12.2外壳设计外壳的厚度,应以设计压力和在下述最小耐受时间内外壳不烧穿为依据:a)电流等于或大于40kA,0.1s;b)电流小于40kA,0.2s。在制定出外壳设计的标准前,不论焊接或铸造的外壳,它的结构和厚度的计算方法应参照类似压力容器的标准,所依据的设计温度和设计压力按本标准确定。对焊接的外壳,制造厂应规定焊缝质量的要求以及焊缝无损探伤的方法和范围。注:设计外壳时,尚应考虑以下各因素:a)外壳充气以前需要抽真空;b)全部压力差可能施加在外壳壁或隔板上;c)在相邻隔室运行压力不同的情况下,因隔室间意外漏气所造成的压力升高d)发生内部故障的可能性(见本标准第6.10条)。外壳的设计温度,通常是周围空气温度的上限加上主回路导体流过额定电流时外壳的温升。当日照有明显作用时,应考虑其影响。20 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.外壳的设计压力至少是在设计温度时,外壳内能达到的压力的上限。在确定外壳的设计压力时,气体温度应取外壳设计温度和在此温度下主回路导体(通过额定电流)温度的平均值。设计压力能从已有的温升试验记录中确定的情况除外。对于未能用计算完全确定其强度的外壳和它的零部件,应进行强度试验(见7.9)。外壳的结构材料应具有已知的和经过检定的最低物理性能,这些性能是计算和/或验证试验的基础。制造厂应对材料的选用负责,并根据材料供应厂的合格证和/或制造厂的进厂检验结果,对保持材料的最低性能负责。5.12.3气体密封性外壳要求高度密封性。制造厂宜按GB11023确定GIS每个封闭压力系统或隔室允许的相对年漏气率。封闭压力系统允许的相对年漏气率应在下列数据中选取≤1%;≤0.5%如用户要求,制造厂应说明通过隔板的允许漏气量,以便在相邻隔室充有一定压力气体的情况下对某一隔室进行维修。5.13隔室GIS应分为若干隔室。其划分方法既要满足正常运行条件,又要使隔室内部的电弧效应得到限制(见6.11)。为此,当相邻隔室因漏气或维修作业而使压力下降时,隔板应能确保本隔室的绝缘性能不发生显著变化。隔板一般由绝缘材料制成,但隔板本身不用来对人身提供电气安全性(对此,可采取例如设备接地的其它措施);然而,对相邻隔室中还存在的正常气体压力,隔板应提供机械安全性。充有绝缘气体的隔室和充有液体的相邻隔室(例如电缆终端或电压互感器)间的隔板,不应出现任何影响两种介质的绝缘性能的泄漏。隔板应按制造厂技术条件进行水压试验、绝缘试验和局部放电试验,必要时还需作超声波探伤试验,以保证质量。GIS的间隔一次模拟图上应标明隔室的具体部位,在设备上应有色标表示。对于GIS的母线较长时,应有适当的气室分隔,以利于设备的运行维护和检修。每个隔室应装有适当数量的吸附剂装置。5.14防爆每个气室应设防爆装置,但满足如下条件之一的也可以不设防爆装置:a)气室分隔的容积足够大,在内部故障电弧发生的允许时限内,压力升高为外壳承受所允许不会发生爆裂。b)制造厂与用户达成协议。防爆装置的防爆膜应保证在使用年限内不会老化开裂。21 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.制造厂应提供防爆装置的压力释放曲线。防爆装置的布置及保护罩的位置,应确保排出压力气体时不危及巡视通道上执行运行任务人员的安全。注:防爆装置包括:a)以开启压力和关闭压力表示其特征的压力释放阀;b)不能再关闭的压力释放装置,如防爆膜。5.14.1限制最大充气压力的压力释放阀当外壳和气源采用固定连接时,所采用的压力调节装置不能可靠地防止过压力,应在外壳上装设适当尺寸的压力释放阀,以防止压力调节装置失效时外壳内部的压力上升到超出设计压力的10%。当外壳和气源不是固定连接时,应在充气管路上装设压力释放阀,以防止外壳充气时气压升到高出设计压力的10%,此阀亦可装在外壳本体上。一旦压力释放阀动作,当压力降低到设计压力的75%之前,阀应重新关闭。充气压力值应考虑当时的气体温度,例如用温度补偿压力表测量。5.14.2在内部故障情况下限制压力升高的压力释放装置鉴于内部故障电弧损坏的外壳将要更换,这种压力释放装置仅用于限制电弧的外部效应(见6.11)。在有些设计中,允许电弧在某些指定的点上将外壳烧穿而获得压力释放。用这种方法生成的孔洞,可看作是压力释放装置,所以它应满足5.14的要求。注1:在内部故障所在的外壳产生塑性变形的情况下,应检查邻近的外壳不存在变形;注2:当采用防爆膜压力释放装置时,其动作压力与外壳设计压力的关系要适当配合,以减少防爆膜误爆破的可能性。5.15联锁为了安全和便于运行,在设备的不同元件之间应设联锁。对主回路必须做到:a)在维修时用来保证隔离间隙的主回路上的高压开关,应确保不自合;b)接地开关合上后应确保不自分。接地开关要与有关的隔离开关互相联锁。隔离开关及某些负荷开关(关合能力低于额定峰值耐受电流或开断能力低于额定电流)要与有关的断路器联锁,以防止断路器处于合闸位置时,隔离开关或这些负荷开关进行分闸或合闸。应按制造厂与用户的协议提供附加的或可供选择的联锁。制造厂应给出了解联锁性能和作22 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.用所需的全部资料。5.16断路器的其他要求按国家电网公司《交流高压断路器技术规范》执行。5.17隔离开关和接地开关按国家电网公司《交流高压隔离开关和接地开关技术规范》执行。5.18电流互感器按国家电网公司《电流互感器技术规范》执行。5.19电压互感器按国家电网公司《电压互感器技术规范》执行。5.20避雷器按国家电网公司《避雷器技术规范》执行。5.21对电缆绝缘试验的规定GIS中和电缆保持连接的部分应能耐受电缆技术规范对同一额定电压的电缆规定的试验电压。如果不允许对GIS的其余部分施加电缆的直流试验电压,则对电缆试验采取特殊的措施(例如,可动或可拆卸的连接和/或增加电缆连接外壳中绝缘气体的密度)。注:直流电压试验时,增加绝缘气体的密度来提高绝缘子表面的电气强度不是一个可靠的办法,采用时要注意。在电缆进行绝缘试验时,GIS的其余部分一般不应带电并应可靠接地,除非采用专门的措施来防止电缆击穿放电时对GIS带电部分的影响。注:在某些情况下,GIS中隔离断口的额定短时工频耐受电压和在隔离断口的一侧施加直流电缆试验电压而另一侧仍带电时隔离断口上的电压之间,实际上并不存在安全裕度,采用时要注意。如有必要,宜在电缆连接外壳上或在GIS本体上设置直流和/或交流试验用套管的安装孔。应用户要求,制造厂可提供试验用套管或给出安装套管的有关资料。5.22GIS出线的连接5.22.1出线和架空线连接5.22.1.1接线端子静态拉力出线套管的接线端子应符合下表规定的静态拉力,静态安全系数为3.2~3.5。应用户要求,可采用其它的型式和尺寸。表10GIS接线端子静态拉力额定值额定电压Ur额定电流I水平拉力Fth/N垂直力Ftv23 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.kVA纵向FthA横向FthBN≤125075040050072.5≥1600750500750≤20001000750750126≥250012507501000252~3631250-3150150010001000550~8002000-4000200015001500注:当要求超过本表规定值时由制造厂和用户双方协商确定。5.22.1.2套管爬电比距套管爬电比距应按GB/T5582的规定进行选择,它们在污秽条件下应当具有良好的电气性能。位于相和地间、相与相间的户外瓷的或有机材料的绝缘子或套管,其外绝缘的最小标称爬电距离用下属关系式确定:lt=α×lr×Ur×KDlt――最小标称爬电距离(mm);α――按表5-8选择的与绝缘类型有关的应用系数;lr――最小标称爬电比距(mm/kV),按GB/T5582的表1选择;Ur――设备的额定电压;KD――直径的校正系数,当直径D≥300mm时,取1.1,当直径D≥500mm时,取1.2。干弧距离和伞型应符合IEC60815的规定。瓷套伞形应为大小伞。无线电干扰及电晕水平在1.1倍额定相电压下无线电干扰电压不大于500μV,晴天夜晚无可见电晕。表11爬电比距的应用系数绝缘的应用部位应用系数α相对地1.0相间3断口1.15注:易被熔化的污雪所覆盖的非直接立安装的绝缘子也可能需要更长的爬电距离。24 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.5.22.2出线和电缆相连电缆终端箱与电缆终端的配合连接应符合IEC859标准的要求。应用户要求进线电缆侧可装设带电显示装置,带电显示装置应有联锁及信号输出接点。每相使用单独的控制器及放大器。设置可取下的连接导体,用于在电缆进行耐压试验时将GIS与电缆隔离。并提供分别对电缆和GIS进行耐压试验的接口设备。试验套管的安装位置在电缆终端箱的上方,通过可拆卸连接导体实现对电缆和GIS分别进行直流和交流耐压试验。出线为双电缆舱时,在设备布置时应考虑便于检修,且其中一路停电检修时,不影响另一路的正常运行。5.22.3出线和变压器直连用户与制造厂协商。5.23伸缩节GIS的平面布置图及剖视图上,应标明伸缩节的位置与数量。伸缩节一般采用不锈钢波纹管结构,也可以是特殊的套筒结构(运行中可以整个间隔抽出来处理故障)。伸缩节主要用于装配调整,吸收基础间的相对位移或热胀冷缩的伸缩量等。制造厂应根据使用的目的、允许的位移量等来选定伸缩节的结构。在GIS分开的基础间允许的相对位移(不均匀下沉)应由制造厂和用户商定。5.24母线母线材质为电解铜或铝合金。铝合金母线的导电接触部位表面应镀银。导电回路的相互连接其结构上应做到:a)固定连接应有可靠的紧力补偿结构,不允许采用螺纹部位导电的结构方式。b)触指插入式连接结构应保证触指接触压力均匀。5.25油漆制造厂应提供色标,供用户选择GIS外壳及箱体的油漆颜色。油漆应保证(8~10)年完好。GIS的接地、SF6气体管道、压缩空气管道等的油漆颜色应按有关标准分别表示以便区分。罐体内部如涂防锈(防腐)漆时,漆面应光滑无异常突起,附着力良好。5.26压缩机及管道系统当GIS采用气动操作时,若压缩机采用集中布置方式,则一般至少设置2组,运行中应同时工作启动,并设置控制保护减压及疏水系统。管道系统一般推荐双母线管道布置,阀门的设置原则要确保在一根母线管道或一台压缩机25 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.检修时仍保证对设备的供气,管道及阀门应采用铜质材料,接头采用卡套式结构。5.27二次回路及就地控制柜原则上每个GIS间隔配置1台控制柜。就地控制柜可以设在GIS底座上与GIS一起运输供货,也可以分开独立设置,当就地控制柜安装在GIS底座架上,应考虑到GIS设备操作振动的影响。当GIS为户外布置时,应按户外条件来考虑柜体的设计结构工艺。柜内应有专用接地母排,截面2不小于100mm。所有二次元件的位置应便于拆装、接线、观察及操作,并有表明其用途的永久性标识。GIS的全部二次线电缆应可靠固定,并全部在专用管道或专用托架中敷设。二次线进出接线盒或柜体部位应可靠封闭并固定。用于所有设备与汇控柜之间的二次连接电缆,及用于电缆敷设和保护的固定电缆线槽应随设备一同供货。交直流电力和控制电缆应选用阻燃型聚乙烯或交联聚乙烯电缆,并应满足lkV电压等级的绝2缘要求。电缆芯线(铜芯)导体截面一般应不得小于2.5mm(电流回路或电源电缆截面根据需要应提高截面尺寸)。4芯以上的多芯控制电缆应留有10%一20%的备用芯,但最少备用芯数不少于2芯。二次走线应与GIS的接地线保持一定距离,要防止内部故障短路电流发生时在二次线上可能产生的分流现象。6型式试验6.1概述按GB11022的第6章,并作如下补充:对GIS中不受GB11022限制的元件,试验时除按各自的标准外还应注意本章给出的规定。作为一般的规则,GIS中的断路器、隔离开关、互感器、避雷器等应按各自的标准进行试验。型式试验应在有代表性的GIS间隔的完整单极或三极功能单元上进行。如确有困难,可在具有代表性的总装或分装上进行。由于元件的型式、参数和可能的组合方式的多样性,因此,对GIS的所有布置方式都进行型式试验是不现实的,任何一种特定布置方式的性能可用可比的布置方式的试验数据来证实。型式试验项目:a)绝缘试验、局部放电试验和辅助回路绝缘试验;b)温升试验和主回路电阻测量;c)主回路和接地回路的短时和峰值耐受电流试验;d)高压开关的开断能力和关合能力试验;e)机械试验;26 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.f)辅助回路和运动部分的防护等级验证;g)外壳强度试验;h)防雨试验;i)气体密封性试验;特殊的型式试验项目(按制造厂和用户协议进行)j)无线电干扰试验;k)内部故障电弧试验;l)极限温度下机械操作试验;m)噪音测量。注:某些型式试验可能影响被试部件继续使用的性能。6.2绝缘试验6.2.1试验时的大气条件按GB11022的第6.2.1条。6.2.2湿试验按GB11022的第6.2.2条,并作如下补充:仅对先前未做过湿试验的户外套管才需要进行试验。对额定电压为252kV及以下的设备,作短时(1min)工频耐受电压试验;对额定电压为363kV及以上的设备,作操作冲击耐受电压试验。试验电压和试验程序应符合GB4109的规定。6.2.3试品条件按GB11022的第6.2.3条中适用的部分。试验应在绝缘气体的最小运行密度下进行。6.2.4试验电压的施加部位GB11022的第6.2.4条不适用。由于GIS设计方案的多样性,对主回路的绝缘试验作出具体的规定是不现实的,但原则上应包括如下试验:a)对地和相间绝缘试验主回路每相的导体应轮流与试验电源的高压接线端子连接,主回路的其它导体和辅助回路的导体则应与接地导体或支架相联,并与试验电源接地端子连接。如有观察窗,绝缘试验时需用接地金属箔将观察窗易接近的一侧盖起来。试验时应将所有高压开关合闸(接地开关除外)。如果高压开关处于分闸位置,其电场情况较合闸时不利,则应在分闸位置重做上述试验。27 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.若为单相—壳式GIS,且出线不用套管时,可仅作对地绝缘试验。注:相间耐受电压大于相对地耐受电压且需进行相间绝缘试验时,试验电压的施加部位按GB311.1-1997的第6.4.3条。b)高压开关的断口绝缘试验主回路中的每一高压开关应在分闸位置,按各自标准的规定进行试验。如果构成GIS整体一部分的电压互感器或电力变压器具有降低的绝缘水千,进行绝缘试验时,上述元件可用再现高压联接件电场的模拟品代替。试验时,过电压保护装置应断开或拆除。若采用上述程序,电压互感器或电力变压器应按各自的标准单独试验。6.2.5试验电压试验电压规定如下:a)对地和相间绝缘试验额定电压72.5kV~252kV,进行雷电冲击耐受电压和短时(1min)工频耐受电压试验。试验电压按GIS的额定绝缘水平在表4-1中选取。额定电压363或550kV,进行雷电冲击耐受电压和操作冲击耐受电压试验。试验电压按GIS的额定绝缘水平在表4-2中选取。b)高压开关的断口绝缘试验根据断路器、负荷开关或隔离开关的工作条件,按各自标准的规定进行雷电冲击耐受电压、操作冲击耐受电压和/或短时(1min)/L频耐受电压试验。试验电压按GIS的额定绝缘水平在表4-1或表4-2中选取。6.2.6雷电冲击耐受电压和操作冲击耐受电压试验按GBll022的6.2.6和6.2.7,并作如下补充:试验时,电流互感器的二次绕组应短路并接地。同时冲击电压发生器的接地端子应连接到GIS的外壳。但按6.2.4a)项的注和b)项进行的某些试验可以例外,必要时,外壳可以对地绝缘,以使任一带电部分和外壳之间的电压不超过6.2.5a)项的规定值。GIS整体(一个或数个功能单元)做雷电和操作冲击耐受电压试验时,也可按GB3116.3.2进行3/9次冲击耐受电压试验。6.2.7主回路短时工频耐受电压试验按GB11022的6.2.6和6.2.7,并作如下补充:GIS的主回路进行短时(1min)工频耐受电压试验时,试验变压器的一端接地并与GIS的外壳相连。但按6.2.4a)项的注和b)项进行的某些试验可以例外,此时,试验变压器的中间抽头(对称加压时为中点)接地并与外壳相连,以使出现在任一带电部分与外壳之间的电压不超过28 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.第6.2.5条a)项的规定值。6.2.8人工污秽试验按GB11022—89的第6.2.8条,并作如下补充:GIS如装有户外套管,且套管预先未进行此试验时,才进行这项试验。6.2.9局部放电试验局部放电测量是一种检查受试设备某些缺陷的合适方法,并且对绝缘试验是一个有益的补充。经验表明,在某些特定结构中,局部放电可导致设备绝缘强度逐渐降低,固体绝缘尤其如此。另一方面,由于GIS绝缘系统的复杂性,局部放电测量结果与设备寿命之间还不可能建立确定的关系。局部放电测量配合其它绝缘试验,可显示是否存在及何处存在由设计所造成的绝缘强度方面的薄弱点。试验应在所有其他绝缘试验后,在同一试品上进行。局部放电测量时绝缘上的场强应尽可能与GIS完整装配中出现在绝缘上的场强相同。6.2.9.1试验回路和测量仪表试验回路和测量仪表见GB7354。试验回路的元件和测量仪表的选择应使其可测量的最小放电量不大于局部放电量规定值的50%。6.2.9.2试验程序将施加的工频电压升高到预加电压值Up,并至少维持10s,然后降低到测量局部放电强度的电压值Ud(Up和Ud均用GIS额定电压U的倍数表示)。单相-壳式GIS在单相试验回路上进行试验。三相—壳式GIS在单相或三相试验回路上进行试验。a)单相-壳式GIS,用于有效接地系统Up=U,Ud=1.1U/√3。b)三相-壳式GIS,用于有效接地系统三相试验回路:外壳连接到电源的中性点,相间的试验电压Up=1.3U,Ud=1.1U;单相试验回路Ⅰ:经制造厂同意,每相的主回路应轮流接到电源,其它相的主回路连同外壳一起接地,试验电压Up=1.3U,Ud=1.1U;29 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.单相试验回路Ⅱ:采用共有一接地端的两个电源进行试验。主电源连接到一相的主回路,辅助电源接到另一相的主回路,其电压值的选择应使这两相间的电压等于主电源电压的√3倍,第三相主回路连同外壳一起接地,主电源应轮流接到每一相的主回路,带电的两相间的试验电压:Up=1.3U,Ud=1.1U;c)单相-壳式GIS,用于非有效接地系统Up=1.3U,Ud=1.1U然后Ud=1.1U/√3。d)三相-壳式GIS,用于非有效接地系统三相试验回路:首先将外壳和电源的中性点接地,然后将各相的主回路轮流和外壳相连后接地,对每一种情况,相间的试验电压Up=1.3U,Ud=1.1U单相试验回路:每相的主回路轮流接入电源,其它相的主回路和外壳一起接地UP=1.3U,Ud=1.1U然后Ud=1.1U/√3。注:如有可能,要考虑实际的背景噪音水平,并记录局部放电起始电压和熄灭电压。6.2.9.3局部放电量的规定值每个间隔的局部放电量不大于5pC,单个绝缘件局部放电量不大于3pC。互感器、套管等元件的局部放电量应由各自的标准规定。6.2.10辅助回路绝缘试验按GB11022的6.2.10,它适用于所有低压辅助回路。电流互感器的二次绕组应短路并与地断开,电压互感器的二次绕组应断开。6.3无线电干扰试验按GB11022的6.3,并作如下补充:仅对装有户外套管的GIS,并按制造厂和用户间的专门协议进行试验。6.4回路电阻测量按GBll022的6.4,并作如下补充:GBll022中关于温升试验前后阻值的允许变化仅适用于GIS中的高压开关。此外,作为型式试验,在工厂中在运输单元上进行所有的测量。6.5温升试验按GB11022的6.5,并作如下补充:如果GIS的设计具有可选择的元件或布置方式,则试验应在造成最苛刻工作条件的那些元件或布置方式上进行。30 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.总装或分装(包括全部正规的外壳)的安装应接近正常使用情况,并应防止额外的外部加热与冷却。除单相—壳式外,应进行三相试验。试验电流等于额定电流。此电流从母线的一个终端流到与电缆或套管相连的接线端。当许可并进行单相试验时,外壳中电流应代表最苛刻的条件。当对单个分装进行试验时,其相邻的分装亦应通以电流,使其能量损耗与额定运行条件吻合。如无法按实际条件试验,则可采用加热器或隔热措施模拟等价条件。不同元件的温升应以周围空气温度为基准折算。其温升不应超过各自标准的规定值。6.6短时和峰值耐受电流试验按GB11022—89的6.6,并作如下补充:三相-壳式GIS应进行三相试验。单相—壳式GIS,应在外壳上通以全部返回电流,进行单相试验。GIS的主回路和接地回路(在工厂中组装的包括接地导体、接地端子和接地开关),在试验时应装上会影响其性能或改变短路电流的所有与其毗连的构件。a)对主回路的试验GIS的主回路应作短时和峰值耐受电流试验。试验后,元件或外壳中导体应不产生妨碍正常运行的变形或损坏。b)对接地回路的试验GIS的接地导体、接地端子和接地开关应进行短时和峰值耐受电流试验。试验后不应有可能影响主回路正常运行的元件或外壳内导体的变形或损坏。接地导体、接地端子或接地开关的某些变形、损坏是允许的,但应保持接地回路的连通性。6.7开断能力和关合能力试验GIS中的高压开关应进行开断能力和/或关合能力试验。制造厂应提供断路器在额定短路开断电流下的累计开断次数。试验按各自的标准进行。试验时,要将所有对其性能有影响的部件(例如联接线、支撑件等)一起装上。注1:在确定哪些部件可能影响性能时,要特别注意短路时的机械力和破坏性放电的可能性等。但在某些情况下这类影响可以完全互略。对单元试验,见GB1984—89的第7章。注2:仅在开断试验时,要考虑在被试部分的端子间和外部连结间的元件的电容。31 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.6.8机械试验GIS中的高压开关设备,均应按各自的标准进行机械试验。此外,为了保证GIS中的高压开关符合规定的操作条件以及联锁正确地工作,所有装有联锁的高压开关应经受50个操作循环,来校验这些联锁的工作情况。在每个操作循环前,这些联锁应置于防止这些高压开关操作的位置,然后对每台高压开关进行一次操作。试验时,主回路不加电压、不通电流,只能使用正常的操作力,并且不应对高压开关和联锁进行调整。若高压开关和联锁处于正确的工作程序,并在试验前后,高压开关所需的操作力基本相同,则认为试验满足要求。若高压开关不能被操作则认为联锁满足要求。6.9辅助回路和运动部分防护等级验证按GB4208第6章的规定进行。对IP5X等级,灰尘的堆积量或位置,不应妨碍设备的正常运行,在绝缘子上灰尘的沉积不应影响其安全运行。仅对满足这些要求有疑问时才进行这项试验。6.10外壳强度试验如果外壳及其零部件的强度未经计算,则要进行强度试验。试验在尚未装入内部元件的单独外壳上进行。强度试验可以是破坏压力试验,亦可以是非破坏压力试验,这与采用的材料相适应。6.10.1破坏压力试验破坏压力试验时,压力升高速度不应大于400kPa/min。破坏压力应不小于:—对铸造外壳为设计压力的3.5倍;—对焊接外壳为设计压力的2.3倍。这些系数是根据外壳材料的最低保证性能而定的。可以用附加系数来考虑制作方法。经过破坏压力试验仍保持完好的任何外壳,应予报废。6.10.2非破坏性压力试验当用应变指示技术进行非破坏性压力试验时,应采用如下程序:-5试验前,把能够显示每毫米应变为5×10mm的应变片贴在外壳表面上。应变片的数目、贴的位置和方向应这样选择:使得所有对外壳完整性有重要意义的各点的主应力和主应变能够得到确定。32 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.试验时,液体静压力以每级大约10%的速度增加,直到达到标准试验压力(其值由预期的设计压力确定(见7.5)或外壳任何部分出现显著变形为止。此时,压力不应继续增大。当压力增加时,读取若干次应变读数,并在卸负荷时重复之。如果外壳无明显的全面变形,局部的永久变形的迹象可以不考虑。若应力-应变的关系曲线表现为非线性,则可重复施加压力,但不多于5次,直到对应于两个连续循环的负载和卸载曲线几乎一致为止。若不能得到这种一致性,那么,设计压力和试验压力应从最后一次卸载曲线的线性部分的压力范围内取。如果标准试验压力在应力—应变关系曲线的线性范围内,则认为达到预期的设计压力。如果最终试验压力或与应变—应力关系曲线线性部分对应的压力上限值低于标准试验压力时,则应按下式计算设计压力:1faP=Pγ-)1.1kft式中:P―设计压力,kPa;Pγ―发生重大变形时的压力或在最后一次卸载时外壳变形最大处的应力-应变关系曲线线性部分的压力上限值,kPa;2fa―试验温度下许用应力,N/mm;2ft―设计温度下许用应力,N/mm;k—标准试验压力系数(见8.5)。非破坏性压力试验的变通程序可以商定。6.11防雨试验经制造厂和用户同意,户外使用的GIS应做防雨试验。试验可按GB7674附录A(标准的附录)中推荐的方法进行。这一试验也计及了风雪的效应。如对设计的审查表明不需要做此项试验,则可免于试验。6.12内部故障电弧试验如经协商要作此试验,试验应按GB7674附录B(标准的附录)所述的方法进行。在电弧试验中采用的试验电流值由制造厂规定,其值应对应于额定短时耐受电流。或者对某些用于中性点绝缘系统的GIS,采用的试验电流值可以是该系统的接地故障电流。对试验要作两个评价:其一,关于在第一段(主)保护动作时限内试品的性能;其二,关于当故障被第二段(后备)保护动作而切除时的情况。在试验时,如果在5.12.2规定的时间内,除了压力释放装置动作外,没有出现其他的外部33 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.效应;并且在0.3s内切除40kA及以上的电流或在0.5s内切除40kA以下的电流时,外壳没有因此而碎裂,则认为GIS满足要求。若制造厂和用户间对电流值和持续时间另有协议,则按协议进行。注:下列数据供参考,由第一段保护切除故障的时间大约是:短路电流40kA及以上为0.1s;40kA以下的电流为0.2s。第二段保护的时间对40kA及以上的电流一般不超过0.3s;对40kA以下的电流,一般不超过0.5s。根据制造厂和用户的协议,经过计算或方案比较,或两种方法结合,某一特定布置上的试验结果可用来预示其他布置的性能。6.13极限温度下机械操作试验6.13.1高温下的操作试验被试的GIS或其元件应该在分闸或合闸位置(这个位置由制造厂和用户商定)置于人工气候室中进行试验,该气候室的温度在五天(120h)内应保持+40℃。在前两天中,试品应不操作。后三天中的任一天,以每四分钟一个操作循环的频率做10个操作循环。试验后应作如下记录:a)操作次数;b)外壳中气体压力;c)经24h的气体泄漏量。应检验这些数值是否还在制造厂对GIS性能所保证的范围内。试验期间,对恒温装置(如有时)亦应验证。6.13.2低温下的操作试验本试验与在高温下的操作试验相同,但试验时人工气候室的温度对应于户内、户外使用条件(见本标准第2章)下的最低周围空气温度。6.14气体密封性试验制造厂应进行气体密封性试验,以验证GIS满足制造厂按5.12.3给出的允许相对漏气率。封闭压力系统和隔室的气体密封性试验按GB11023。对GIS中具有特定密封结构的每种隔室的气体密封性测量,作为一种型式试验,应分别与6.7和6.12的试验一起进行,以证实漏气率不因上述试验的影响而变化。如有需要,亦可进行通过隔板漏气的密封试验(见本标准第5.12.3条)。注:对于通过隔板漏气的密封试验,可把一个隔室抽真空,而相邻隔室充以额定密度的气体,经24h之后测量被抽空隔室的压力升高。6.15噪音测量在离地(或工作面)高1~1.5m、距GIS外沿垂直面的水平距离2m处,用声级计测量高压开34 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.关操作时的冲击噪音水平。测量方法参照GB3222。6.16断路器断路器的型式试验项目见表12。表12型式试验项目序号型式试验项目包含内容1绝缘试验工频电压试验雷电冲击电压试验操作冲击电压试验作为状态检查的电压试验人工污秽试验和凝露试验局部放电试验2机械试验机械特性试验;机械寿命试验3回路电阻测量4温升试验5短时耐受电流和峰值耐受电流试验6出线端短路条件下的关合和开断试验出线端故障的试验方式1、2、3、4、5;额定短路开断电流下的连续开断能力(电寿命)试验;7容性电流开合试验线路充电电流开合试验(Ur≥72.5kV)电缆充电电流开合试验(Ur≤40.5kV)8无线电干扰电压试验9EMC试验10密封试验11辅助和控制回路的附加试验适用于直接与架空线连接的、额定电压72.5kV及以12近区故障试验上且额定短路开断电流超过12.5kA的三极断路器。13失步关合和开断试验适用于有额定失步开断能力的断路器。14单相和异相接地故障试验适用于中性点对地绝缘系统中的断路器。15临界电流开合试验适用于具有临界电流的断路器。线路充电电流开合试验(Ur≤40.5kV)16容性电流开合试验电缆充电电流开合试验(Ur≥72.5kV)35 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.序号型式试验项目包含内容单个电容器组开合试验背对背电容器组开合试验―并联电抗器开合试验;17感性电流的开合试验―感应电动机开合试验。低温试验和高温试验18环境试验湿度试验严重冰冻条件下的操作验证试验淋雨试验IP代码的检验19防护等级验证机械撞击试验20耐受地震试验21噪声水平测试各项型式试验项目均应按照GB1984第6章规定的试验方法和试验程序进行试验。6.17隔离开关6.17.1型式试验项目型式试验项目见表13表13型式试验项目序号型式试验项目包含内容1绝缘试验工频电压试验雷电冲击电压试验操作冲击电压试验并联绝缘体人工污秽试验和湿耐压试验局部放电试验户内产品的凝露试验2操作和机械寿命试验机械特性试验;机械操作试验机械寿命试验接触区试验端子静态机械负荷试验隔离开关与接地开关联锁性能试验3回路电阻测量4温升试验5短时耐受电流和峰值耐受电流试验6无线电干扰电压试验7EMC试验36 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.8密封试验9辅助和控制回路的附加试验10接地开关短路关合性能试验11严重冰冻条件下的操作试验12极限温度下的操作试验13位置指示装置正确功能试验14隔离开关母线转换电流开合能力试验15接地开关感应电流开合能力试验金属封闭开关设备的隔离开关的母线充电16电流开合能力试验隔离开关开合小的电容性电流和电感性电17流的试验环境试验低温试验和高温试验18湿度试验;淋雨试验防护等级验证IP代码的检验19机械撞击试验20耐受地震试验21噪声水平测试6.17.2型式试验的其它要求1)温升试验参见GB/T1985的6.5条,并对温升值的裕度作如下补充。2000A及以上产品的温升试验电流为产品的额定电流,但温升的裕度应大于各点标称温升值的10%。2)主开关和接地开关机械联锁的强度试验:主开关和接地开关机械联锁应具有足够的机械强度,当发生电动或手动误操作时,应能可靠闭锁,不得损坏任何元器件。6.18构成GIS的其他主要元件包括互感器设备和避雷器,型式试验应符合各自标准。7出厂试验应整体或按间隔进行出厂试验,试验项目如下:a)主回路绝缘试验;b)辅助回路绝缘试验;c)主回路电阻测量;d)局部放电试验;e)外壳压力试验;f)气体密封性试验;37 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.g)机械试验;h)电气、气动和其他的辅助装置试验;i)接线检查;k)六氟化硫气体的水分含量测定。注:必要时要验证同样额定值及结构的元件的互换性。7.1主回路绝缘试验按本标准第6.2.1条、第6.2.3条、第6.2.4条和第6.2.7条,对GIS主回路的相对地、相间(如有需要)以及高压开关的断口进行短时(1min)工频耐受电压试验。试验电压采用同一数值,按GIS的额定绝缘水平在表4-1栏(4)和表4-2栏(8)中选取。7.2辅助回路绝缘试验按本标准第6.2.10条。7.3主回路电阻测量.按本标准第6.4条,并作如下的补充:在工厂中,在运输单元上进行所有的测量。高压开关处于合闸位置时测得的电阻不应超过1.2Ru,Ru是型式试验时测得的相应的电阻。7.4局部放电试验试验按本标准第6.2.9条,但仅对运输单元或元件进行。元件出厂的局部放电试验,按各自标准的规定进行。GIS中树脂浇铸绝缘件(如盆式绝缘子、拉杆等)的局部放电量应逐个检查。经制造厂和用户协商,出厂试验方可作为验收试验。7.5外壳压力试验所有外壳制造好之后应进行压力试验,试验压力应为设计压力的k倍,对于焊接外壳k=1.3;对于铸造外壳k=2.0。7.5气体密封性试验按本标准第6.14条规定。7.7机械试验GIS中的高压开关,均应按各自的标准进行出厂机械试验。试验方法按GB3309。此外,为了保证GIS中的高压开关符合规定的操作条件以及联锁正确地工作,所有装有联锁的高压开关应经受5个操作循环,来校验这些联锁的工作情况。38 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.7.8电气、气动和其他的辅助装置试验电气的、气动的和其他的联锁与具有预定操作顺序的控制装置一起,应在规定的使用和运行条件下,在辅助能源最不利的极限数值下连续试验5次,试验期间不应调整。如果辅助装置操作正常,在试验后仍处于良好运行状况,则认为试验合格。7.9接线检查应检验接线是否符合接线图和规定的要求。7.10SF6气体的水分含量测定如果GIS是充SF6气体的,设备中SF6气体的水分含量测定应按GB8905,并在充气48h后进行。注:如制造厂的经验表明出厂时GIS中SF6气体的水分含量符合规定,则可免去这项试验。7.11断路器出厂试验项目1)对主要零部件的出厂试验应包括:―断口均压电容;―有机绝缘子;―绝缘拉杆;―并联电阻。这些零部件的试验项目及标准均应满足各自相关的国家或行业标准的要求。2)整台产品的出厂试验项目断路器的出厂试验应在整体组装后进行,对整台产品的出厂试验项目见表14。表14试验项目序号试验项目试验内容1主回路的绝缘试验短时工频电压干试验;有机绝缘部件的局部放电试验或直流泄漏电流试验。2辅助回路和控制回路的试验辅助和控制回路的检查及电路图和接线图的一致性验证;功能试验;电击防护的验证;绝缘试验(工频试验)。3主回路电阻的测量4密封试验5机械特性和机械操作试验机械操作试验;机械特性试验(包括分闸时间、合闸时间、分―合时间、合39 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.-分时间、分闸不同期性、合闸不同期性、机械行程特性曲线、合闸电阻的提前投入时间和退出时间、辅助开关的切换与主断口动作时间的配合等)。6设计检查与外观检查设计与外观检查用以证明产品符合买方的技术要求所有这些出厂试验项目均应按照GB1984第7章规定的试验方法和试验程序进行试验。产品出厂必须附有合格的出厂试验报告。7.12隔离开关出厂试验项目整台产品出厂试验项目见表15。表15出厂试验项目序号试验项目试验内容1主回路的绝缘试验绝缘电阻试验短时工频电压干试验;363kV及以上操作冲击耐压试验有机绝缘部件的局部放电试验或直流泄漏电流试验。2辅助回路和控制回路的试验辅助和控制回路的检查及电路图和接线图的一致性验证;功能试验;电击防护的验证;绝缘试验(工频试验)。3主回路电阻测量及触指接触压力测量4密封试验5机械试验机械操作试验;机械特性试验;隔离开关与接地开关联锁性能试验。6设计检查与外观检查设计与外观检查用以证明产品符合买方的技术要求7.13构成GIS的其他主要元件包括互感器设备和避雷器,出厂试验应符合各自标准。8现场交接试验8.1GIS现场交接试验项目包括:a)外观检查;b)主回路电阻测量;c)元件试验;d)SF。气体的验收;e)气体密封性试验;40 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.f)SF6气体湿度测量;g)主回路绝缘试验;h)局部放电测量;i)辅助回路绝缘试验;j)联锁试验;k)气体密度装置及压力表校验。8.2外观检查(1)检查GIS整体外观,包括油漆是否完好、有无锈蚀损伤、高压套管有否损伤等。(2)检查各种充气、充油管路,阀门及各连接部件的密封是否良好;阀门的开闭位置是否正确;管道的绝缘法兰与绝缘支架是否良好。(3)检查断路器、隔离开关及接地开关分、合闸指示器的指示是否正确。(4)检查各种压力表、油位计的指示值是否正确。(5)检查汇控柜上各种信号指示、控制开关的位置是否正确。(6)检查各类箱、门的关闭情况是否良好。(7)检查隔离开关、接地开关连杆的螺丝是否紧固,检查波纹管螺丝位置是否符合制造厂的技术要求。(8)检查所有接地是否可靠。8.3主回路电阻测量(1)制造厂应提供每个元件(或每个单元)的回路电阻值。测试值应符合产品技术条件的规定,并不得超过出厂实测值的120%,还应注意三相平衡度的比较。(2)回路电阻测量一般可采用以下方法:1)应采用直流压降法,测试电流不小于100A。2)有引线套管的可利用引线套管注入测量电流进行测量。3)若接地开关导电杆与外壳绝缘时,可临时解开接地连接线,利用回路上的两组接地开关导电杆关合到测量回路上进行测量。4)若接地开关导电杆与外壳不能绝缘分隔时,可先测量导体与外壳的并联电阻R0和外壳的直流电阻R1,然后按下式换算:R0R1R=R1-R08.4元件试验(1)各元件试验按GB50150—91《电气装置安装工程电气设备交接试验标准》进行试验。41 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.(2)若金属氧化物避雷器、电磁式电压互感器与母线之间连接有隔离开关,在工频耐压试验前做老练试验时,可将隔离开关合上,加额定电压检查电磁式电压互感器的变比以及金属氧化物避雷器阻性电流和全电流。工频耐压试验时,要打开隔离开关。(3)若金属氧化物避雷器、电磁式电压互感器与母线之间连接无隔离开关,工频耐压试验前不能装上去,待工频耐压试验后再装回去,装回后加额定电压检查电压互感器变比、金属氧化物避雷器阻性电流和全电流。(4)若交流耐压试验采用调频电源时,电磁式电压互感器经计算其频率不会引起磁饱和,可与主回路一起进行耐压试验。8.5SF6气体的验收(1)应检查充人GIS内新气的质量证明书(其内容包括:生产厂名称、产品名称、气瓶编号、净重、生产日期和检验报告单)。(2)充入GIS内新气按规定抽样进行质量复核,应符合表5-1的要求。(3)若是国外进口的新气,也应抽样进行质量复核,并应符合表5-1的要求。(4)充入GIS的每瓶气体,充前都应进行气体湿度测量,并符合表5-2的要求,湿度超标者不得使用。8.6气体密封性试验(1)GIS的密封性试验,应按GBll023有关规定进行,每个隔室的年漏气率不应大于1%。检漏必须在充气24h后进行。(2)密封性试验分定性检漏和定量检漏两个部分。(3)定性检漏:定性检漏仅作为检测试品漏气与否的一种手段,是定量检漏前的预检。通常采用抽真空检漏和检漏仪检漏两种方法。a)抽真空检漏:当试品抽真空到真空度已达到或小于133Pa时,再继续抽真空30min后停泵,静止30min后读取真空度A,再间隔5h后读取真空度B,若B—A≤133Pa,则认为试品密封性能良好。b)检漏仪检漏:用灵敏度不低于1PL/L的气体检漏仪沿着外壳焊缝、接头结合面,法兰密封、转动密封、滑动密封面,表计接口等部位,用不大于2.5mm/s的速度在上述部位缓慢移动,检漏仪应无反应。则认为试品密封性能良好。(4)定量检漏:应在充到额定气压24h后进行。定量检漏可以在整台设备或每个隔室进行。通常采用局部包扎法。局部包扎法是将试品的密封面用塑料薄膜包扎,经过一定时间后,测定包扎腔内SF6气体的浓度并通过计算确定年漏气率的方法。8.7SF6气体湿度测量(1)SF6气体湿度测量必须在充气至额定气体压力下24h后进行。测量时,环境相对湿度一般不42 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.大于85%。(2)SF6气体湿度交接验收标准见表5。(3)通常测量SF6气体湿度的方法有露点法、电解法、阻容法等。各种方法所用仪器必须每年定期送检。8.8主回路绝缘试验(1)本试验应在其他试验项目完成后进行。现场耐压试验的目的是检查总体安装后的绝缘性能是否完好,验证是否存在各种隐患(如安装错误,包装、运输、储存和安装调试中的损坏,存在异物等)导致内部故障。耐压试验前,应制定详细的试验方案。(2)试品要求试品应完全安装好,充气到额定密度,并进行密封性试验和气体湿度测量合格后,才能进行耐压试验。(3)耐压试验前,应对试品测绝缘电阻。(4)耐压试验前,GIS上所有电流互感器的二次绕组应短路并接地。下列部件由于它们的充电电流大,或者由于它们的电压限制效应,要求被隔开:a)高压电缆和架空线;b)电力变压器和大多数电磁式电压互感器(如采用变频电源,电磁式电压互感器经频率计算;不会引起磁饱和,也可以和主回路一起耐压);c)避雷器和保护火花间隙。应注意试验完成后,重新连接隔离部件的过程中可能引入事故的情况。(5)GIS的每一新安装部分都应进行耐压试验。(6)GIS的扩建部分进行耐压试验时,相邻设备原有部分应断电并接地。否则,对于突然击穿给原有部分设备带来的不良影响应采取特殊措施。(7)GIS在设备的扩建部分进行耐压试验时,可能需要通过原有部分施加电压,在这种情况下,其试验程序与新安装的GIS相同。8.9局部放电测量局部放电测量有助于检查GIS内部多种绝缘缺陷,因而它是安装后耐压试验很好的补充。由于环境干扰,此项工作比较困难,试验结果的判断需要一定的经验。建议凡有条件和可能的地方,应进行局部放电试验。现场局部放电试验按照DL/T617—1997中有关条款的规定进行。局部放电试验应在耐压试验后,在同一试品上进行。也可以在交流耐压试验的同时进行。为了提高局部放电检测的效果,需尽量减少电源和环境干扰,避免高压引线电晕的发生(如GIS高压引入套管的屏蔽和采用无电晕的大直径导线等)。43 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.8.10辅助回路的绝缘试验辅助回路应耐受2000V工频耐压1min。耐压时,电流互感器二次绕组应短路并与地断开;电压互感器二次绕组应断开。8.11联锁试验GIS的不同元件之间设置的各种联锁均应进行不少于3次的试验,以检验其正确功能。各种连锁主要是指:a)接地开关与有关隔离开关的互相联锁。b)接地开关与有关电压互感器的互相联锁。c)隔离开关与有关断路器的互相联锁。d)隔离开关与有关隔离开关的互相联锁。e)双母线接线中的隔离开关倒母线操作联锁。8.12气体密度装置及压力表校验气体密度装置应校验其接点动作值与返回值,并符合其产品技术条件的规定。压力表指示值的误差与变差,均应在产品相应等级的允许误差范围内。校验方法可以用标准表在设备上进行核对,也可在标准校验台上进行校验。9备品备件及专用工器具9.1备品备件用户订货时原则上对备品备件仅考虑GIS在运行维护和小修检查时的用量。若本体中的元器件发生故障,用户可与制造厂具体协商购置。推荐用户考虑的备品备件如下:a)分、合闸线圈;b)就地控制柜中个别易损的操作开关等二次元件;c)SF6气体压力表;d)适量的密封圈;e)SF6阀门,空气阀门;f)SF6气体;g)密度继电器。注:用户也可要求制造厂对所供设备提出一份推荐的备品备件与消耗品的清单(包括备品的结构图与建议的使用寿命)9.2专用工器具专用工器具配置视用户具体要求而定(若已配备部分专用工器具,订购时可酌情减少)。用户也可要求制造厂对设备安装、运行与维护中所需的专用工器具列出清单,并说明技术规范和推荐的生产厂家。推荐的专用工器具如下。44 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.a)检修专用工具:如断路器喷口、触头拆装工具(或灭弧室拆装工具);b)隔离开关、接地开关触头拆装工具;c)各种力矩扳手、专用螺丝刀等;d)断路器、隔离开关、接地开关手动操动工具;e)气体回收装置;f)SF6气体检漏仪;g)试验套管:交流,h)简易充气装置;i)湿度测试仪;j)真空计;k)绝缘试验专用的互感器。注:地下变电站或水电站坝内布置的GIS可考虑配置专用的互感器。10GIS的选用导则根据使用要求,确定GIS各个元件在正常负荷条件和故障条件下要求的额定值,以此来选用GIS。建议选用本标准给出的额定值,选用时要考虑系统的特点及其今后预期的发展。额定值见第4章。仅对外绝缘,才考虑诸如当地的大气和气候条件以及在海拔超过1000m处使用的影响(见本标准第4章)。11查询和订货时提供的资料当查询或订购GIS时,查询者宜提供下列资料:11.1系统的特征标称电压和系统最高电压、频率和系统中性点接地的型式。11.2工作条件最低和最高周围空气温度,超越正常使用条件或影响设备良好运行的条件,例如,不寻常地暴露在蒸汽;潮气、烟雾、易爆气体、过量的灰尘或盐雾中,地震的危险或由外部造成的传递到设备来的其他振动,以及基础可能的位移。11.3设备及其元件的特征a)户内或户外装置;b)三相—壳式或单相—壳式;c)母线组数;45 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.d)额定电压;e)额定绝缘水平;f)母线和支线的额定电流;g)额定短时耐受电流;h)额定短路持续时间;i)额定峰值耐受电流;j)元件的额定值;k)辅助回路和远动部分的防护等级;l)电路接线图;m)高压电缆连接的细节。11.4操动机构的特征a)操动机构的型式;b)额定电源电压(如有时);c)额定电源频率(如有时);d)额定气源压力(如有时);e)特殊的联锁要求。除这些项目外,查询者宜指明可能影响投标和订货的每一种情况,例如,特殊的安装条件、外部高压连接线的位置、接地要求或压力容器的规程。如果要做特殊的型式试验宜提出资料。12投标时提供的资料如果可行,制造厂宜以文字描述和图示方式提供下列资料:12.1额定值和特征列举在11.3中的设备的特征。12.2设备及其元件的更详细情况a)外壳的设计压力;b)外壳的设计温度;c)绝缘用气体的种类和额定密度;d)最小运行密度;e)不同间隔的气体容积;f)气体泄漏和水分含量的极限值;g)故障定位适用方法的细节。46 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.12.3型式试验证书或报告12.4结构特征a)最重运输单元的质量;b)设备的外形尺寸;c)外部连接的布置方案;d)由用户进行运输的规定;e)由用户进行安装的规定。12.5操动机构的特征a)列举在11.4中的型式和额定值;b)操作功率或电流;c)动作时间;d)操作时排出的气体量。12.6有关需经制造厂和用户预先协商的所有事项的资料12.7推荐的备件、专用工具和试验用附件清单列出用户应得到的备件、专用工具和试验用附件。12.8运行和维护的说明。13运输、贮存、安装、运行和维护GIS或其运输单元的运输、贮存、安装、运行和维护应按照制造厂给出的说明书进行,运输、贮存、安装、运行和维护的说明书应在交货前三个月提供。各元件的相关标准中规定的关于其运输、安装、运行和维护的要求,如适用,亦应包括在GIS有关部分的说明书内。13.1运输、贮存和安装的条件GIS应在密封和充低压力的干燥气体(如SF6或N2)的情况下包装、运输和贮存,以免潮气侵入。GIS应有包装规范,并应能保证各组成元件在运输过程中不致遭到破坏、变形、丢失及受潮。对于外露的密封面,应有预防腐蚀和损坏的措施。各运输单元应适合于运输及装卸的要求,并有标志,以便用户组装。包装箱上应有运输、贮存过程中必须注意事项的明显标志和符号(如向上、怕湿、小心轻放、由此吊起和重心点等)。出厂产品应附有产品合格证书(包括出厂试验数据)和装箱单。如果订货时规定的使用条件在运输、贮存和安装时得不到保证,制造厂和用户应达成一项特别的协议,并采取必要措施。47 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.13.2安装13.2.1开箱和起吊运输单元的质量、起吊和开箱的注意事项和专用的起吊用具等。13.2.2组装不是整体运输的GIS,其运输单元应有清楚的标志和代号,并应提供注有运输单元代号的组装示意图,以便在组装前检查GIS交付的完整性。13.2.3安装的准备提供基础施工的要求,外部接线端子的尺寸,电缆进入地点的位置,接地以及各种管道(对户外装置还包括雨水排泄管道)的连接方式、尺寸和布置资料,以便进行现场的准备工作。13.2.4最后的安装验收推荐在现场进行的试验明细表。13.3维护维护说明书至少包括:按相关标准的规定,提供主要元件的完整的维护说明(例如断路器在额定短路开断电流下的累计开断次数及检修周期等),以及GIS维修工作的分类和程序、检修周期、检修时的安全措施和绝缘气体的管理等方面的资料。13.4运行除了元件的详细的使用说明书外,应提供有关GIS安全运行(如接地、绝缘气体的监控和联锁等)的资料。48 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.气体绝缘金属封闭开关设备技术标准编制说明本标准主要依据GB7674《72.5kV及以上气体绝缘金属封闭开关设备》,并引用了国网公司高压开关设备技术规范的对有关重点内容。本标准主要以全面、严格、简单、实用为原则,即既要满足对设备提出全面、严格的质量标准,又要满足方便用户设备选用、订货和使用的需要,因而突出对六氟化硫组合电器整体和构成六氟化硫组合电器的高压开关类设备的全面、严格的技术要求、试验要求以及设计和结构的要求,并考虑实际工作需要对于六氟化硫组合电器现场交接试验进行重点说明。本标准重点补充了DL/T618《气体绝缘金属开关封闭设备现场交接试验规程》部分内容。本标准对高压开关设备未包含试验方法和试验程序以及部分相关设备(如:电流互感器、电压互感器、避雷器等)等方面的内容,有关内容可参考相应国家、行业及国家电网公司标准。对于构成六氟化硫组合电器的主要元件高压开关设备,国网公司相应标准所采纳的国标和行标的最新变化和规定,本标准同样适用。包括:DL/T593中关于开关设备电磁兼容(EMC)较为详细的规定;DL/T593中关于开关设备辅助和控制设备设计和结构方面非常详细的规定;武汉会议对断路器的合分时间的最新规定;针对气动机构在寒冷地区使用过程中出现的问题,对气动机构的设计和制造提出了空气管路加热、加装气水分离装置的要求等。以及几个需重点说明的问题:(1)关于合-分时间主要说明以下三点:1)由于断路器合-分时间加长时,对系统稳定性起着不利影响,而合-分时间过短又不利于断路器重合闸时第二个“分”的可靠开断能力,因此合-分时间应该有个范围,制造厂应给出断路器合-分时间的上下限,并应在型式试验中验证断路器在规定的最小合-分时间下的额定短路开断能力。2)对126kV及以上断路器合-分时间应不大于60ms,推荐不大于50ms。3)为与快速保护装置配合,保证重合闸时第二个“分”的可靠开断能力,断路器应具有自卫能力。(2)关于断路器电寿命的规定:对于40.5kV以上的高压断路器,需进行额定短路开断电流下的连续开断能力试验(电寿命试验)。断路器在其主回路中开断用的零件不要维修的情况下,可连续开断额定短路开断电流的次数应由下列数值中选取:16,20,25次。49 GeneratedbyFoxitPDFCreator©FoxitSoftwarehttp://www.foxitsoftware.comForevaluationonly.3)用于频繁操作(如投切电容器、电抗器、电动机等)的断路器,其开合额定电流的次数不低于其机械寿命次数。(3)关于断路器机械寿命的规定:断路器按照机械寿命的不同分为两类:1)M2级(延长的机械寿命):用于特殊使用要求的、适合于频繁操作的、要求非常有限的维护且通过特定的型式试验验证的断路器(具有延长的机械寿命的断路器)。a)M2级的真空断路器的机械寿命应根据需要从下列数值中选取:10000次、20000次、30000次。b)M2级的SF6断路器的机械寿命应根据需要从下列数值中选取:10000次、20000次。2)M1级(基本的机械寿命):不属于M2级断路器范畴内的、具有基本的机械寿命的断路器。M1级的SF6断路器的机械寿命应根据需要从下列数值中选取:5000次。(4)关于温升试验:为保证断路器设备的良好载流能力,防止运行中过热,要求制造厂在设计制造断路器时,应考虑产品的温升具有一定的裕度。50'